INSERT INTO `Table` (`Temperature T , in °C`, `factor A`, `factor B , in MPa`) VALUES (40, 0.0002, 21), (40, 0.0009, 92), (40, 0.002, 108), (40, 0.003, 117), (40, 0.004, 122), (40, 0.005, 127), (40, 0.007, 132), (40, 0.009, 135), (40, 0.012, 138), (40, 0.1, 138), (95, 0.0002, 21), (95, 0.0009, 92), (95, 0.002, 108), (95, 0.003, 117), (95, 0.004, 122), (95, 0.005, 127), (95, 0.1, 127), (205, 0.0002, 19), (205, 0.00095, 94), (205, 0.002, 108), (205, 0.0025, 112), (205, 0.003, 114), (205, 0.004, 177), (205, 0.1, 177), (425, 0.0002, 17), (425, 0.00095, 86), (425, 0.002, 97), (425, 0.003, 101), (425, 0.004, 102), (425, 0.005, 103), (425, 0.1, 103), (650, 0.00025, 21), (650, 0.001, 83), (650, 0.002, 94), (650, 0.003, 99), (650, 0.004, 100), (650, 0.005, 101), (650, 0.1, 101), (730, 0.00025, 19), (730, 0.001, 79), (730, 0.002, 90), (730, 0.003, 94), (730, 0.004, 97), (730, 0.1, 97), (760, 0.00025, 19), (760, 0.001, 78), (760, 0.1, 78), (790, 0.00025, 19), (790, 0.001, 59), (790, 0.1, 59), (815, 0.00025, 19), (815, 0.001, 42), (815, 0.1, 42)