INSERT INTO `Table` (`Temperature T , in °C`, `factor A`, `factor B , in MPa`) VALUES (40, 0.0000143, 1.38), (40, 0.0006, 57.9), (40, 0.007, 91.7), (40, 0.01, 96.5), (40, 0.02, 105), (40, 0.05, 112), (40, 0.1, 112), (150, 0.0000153, 1.38), (150, 0.000475, 43.1), (150, 0.005, 68.6), (150, 0.006, 70.3), (150, 0.01, 75.8), (150, 0.0458, 86.9), (150, 0.1, 86.9), (205, 0.0000154, 1.38), (205, 0.00041, 37.1), (205, 0.007, 61.7), (205, 0.01, 64.8), (205, 0.0429, 73.1), (205, 0.1, 73.1), (315, 0.0000169, 1.38), (315, 0.000363, 30.2), (315, 0.005, 49.6), (315, 0.01, 54.5), (315, 0.0456, 62.1), (315, 0.1, 62.1), (425, 0.0000176, 1.38), (425, 0.000317, 25), (425, 0.005, 41), (425, 0.01, 45.5), (425, 0.0468, 53.1), (425, 0.1, 53.1)