INSERT INTO `Table` (`Temperature T , in °C`, `factor A`, `factor B , in MPa`) VALUES (40, 0.0000139, 1.38), (40, 0.000535, 52.1), (40, 0.002, 69.6), (40, 0.006, 85.5), (40, 0.04, 103), (40, 0.1, 103), (205, 0.0000158, 1.38), (205, 0.000361, 31.9), (205, 0.001, 37.9), (205, 0.01, 56.2), (205, 0.0283, 67.2), (205, 0.1, 67.2), (315, 0.0000165, 1.38), (315, 0.000319, 26.8), (315, 0.001, 32.8), (315, 0.01, 49), (315, 0.0281, 58.3), (315, 0.1, 58.3), (425, 0.0000174, 1.38), (425, 0.000275, 21.9), (425, 0.0015, 29.4), (425, 0.01, 40.7), (425, 0.03, 49.6), (425, 0.1, 49.6)