INSERT INTO `Table` (`Temperature T , in °C`, `factor A`, `factor B , in MPa`) VALUES (38, 0.00001, 0.975), (38, 0.000103, 10), (38, 0.00125, 122), (38, 0.00224, 151), (38, 0.00401, 183), (38, 0.00949, 195), (38, 0.0429, 207), (38, 0.075, 214), (93, 0.00001, 0.951), (93, 0.000105, 10), (93, 0.00111, 106), (93, 0.00276, 136), (93, 0.00614, 151), (93, 0.0164, 158), (93, 0.0572, 166), (93, 0.075, 169), (204, 0.00001, 0.951), (204, 0.000109, 10), (204, 0.00108, 98.8), (204, 0.00323, 113), (204, 0.00678, 124), (204, 0.018, 135), (204, 0.0747, 143), (316, 0.00001, 0.872), (316, 0.000115, 10), (316, 0.000979, 85.4), (316, 0.00377, 109), (316, 0.00838, 123), (316, 0.0241, 132), (316, 0.075, 139), (427, 0.00001, 0.83), (427, 0.00012, 10), (427, 0.000884, 73.5), (427, 0.00228, 94.6), (427, 0.0059, 116), (427, 0.0121, 123), (427, 0.0219, 127), (427, 0.0555, 133), (427, 0.075, 136)